linux硬盘管理 raid |
您所在的位置:网站首页 › lsi raid foreign › linux硬盘管理 raid |
服务器有部分硬盘报警 需要更换 刚接手服务器不知道具体情况 百度了一些教程 都不尽人意 查询结果都没有想要的 后找到一篇文章 地址 http://blog.csdn.net/msdnchina/article/details/52475383 我这里只写与我实际操作有出入的地方 以备复习 cat /proc/scsi/scsi dmesg | grep -i raid lsi MegaRAID raid卡管理工具能查如下信息: raid的level, raid是几块物理硬盘构成的, 物理硬盘的制造商. 软件raid:查看raid级别,状态等信息 #cat /proc/mdstat 硬件raid:查看raid的厂商,型号,级别 #cat /proc/scsi/scsi dmesg | grep -i raid dracut: rd_NO_MD: removing MD RAID activation megaraid_sas 0000:03:00.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 megaraid_sas 0000:03:00.0: setting latency timer to 64 megaraid_sas 0000:03:00.0: FW now in Ready state megaraid_sas 0000:03:00.0: irq 107 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 108 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 109 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 110 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 111 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 112 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 113 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 114 for MSI/MSI-X megaraid_sas 0000:03:00.0: firmware supports msix : (16) megaraid_sas 0000:03:00.0: current msix/online cpus : (8/8) megaraid_sas 0000:03:00.0: RDPQ mode : (disabled) megaraid_sas 0000:03:00.0: Current firmware maximum commands: 1008 LDIO threshold: 0 megaraid_sas 0000:03:00.0: Init cmd success megaraid_sas 0000:03:00.0: firmware type : Legacy(64 VD) firmware megaraid_sas 0000:03:00.0: controller type : MR(512MB) megaraid_sas 0000:03:00.0: Online Controller Reset(OCR) : Enabled megaraid_sas 0000:03:00.0: Secure JBOD support : No megaraid_sas 0000:03:00.0: INIT adapter done megaraid_sas 0000:03:00.0: Jbod map is not supported megasas_setup_jbod_map 4967 megaraid_sas 0000:03:00.0: pci id : (0x1000)/(0x005b)/(0x1028)/(0x1f38) megaraid_sas 0000:03:00.0: unevenspan support : no megaraid_sas 0000:03:00.0: firmware crash dump : no megaraid_sas 0000:03:00.0: jbod sync map : no scsi0 : Avago SAS based MegaRAID driver megaraid_sas 0000:03:00.0: scanning for scsi0... megaraid_sas 0000:03:00.0: 4145 (529973269s/0x0001/CRIT) - VD 00/0 is now DEGRADED megaraid_sas 0000:03:00.0: scanning for scsi0... 软件下载地址http://www.avagotech.com/support/download-search 在搜索框里搜索"megacli",点击确定,找到Management Software and Tools (22) 下的 MegaCLI 5.5 P2 (这是命令行工具),另:lsi已经被avago收购了. [root@F11 ~]# mv 8-07-14_MegaCLI.zip 123/ [root@F11 ~]# cd 123/ [root@F11 123]# unzip 8-07-14_MegaCLI.zip Archive: 8-07-14_MegaCLI.zip inflating: 8.07.14_MegaCLI.txt inflating: DOS/MegaCLI.exe extracting: FreeBSD/MegaCLI.zip extracting: FreeBSD/MegaCli64.zip inflating: Linux/MegaCli-8.07.14-1.noarch.rpm inflating: Solaris/MegaCli.pkg inflating: Windows/MegaCli.exe inflating: Windows/MegaCli64.exe [root@F11 123]# ls -lrt total 7824 -rw-r--r-- 1 root root 48298 Jan 19 2014 8.07.14_MegaCLI.txt -rw-r--r-- 1 root root 7939395 Dec 8 10:34 8-07-14_MegaCLI.zip drwxr-xr-x 2 root root 4096 Dec 8 10:36 DOS drwxr-xr-x 2 root root 4096 Dec 8 10:36 FreeBSD drwxr-xr-x 2 root root 4096 Dec 8 10:36 Linux drwxr-xr-x 2 root root 4096 Dec 8 10:36 Solaris drwxr-xr-x 2 root root 4096 Dec 8 10:36 Windows [root@F11 123]# cd Linux/ [root@F11 Linux]# LS -L -bash: LS: command not found [root@F11 Linux]# ls -l total 1516 -rw-r--r-- 1 root root 1549650 Dec 16 2013 MegaCli-8.07.14-1.noarch.rpm [root@F11 Linux]# rpm -ivh MegaCli-8.07.14-1.noarch.rpm Preparing... ########################################### [100%] 1:MegaCli ########################################### [100%] [root@F11 Linux]# cd /opt/MegaRAID/MegaCli/ [root@F11 MegaCli]# ls -l total 3188 -rw-r--r-- 1 root root 0 Dec 8 10:37 install.log lrwxrwxrwx 1 root root 48 Dec 8 10:37 libstorelibir-2.so -> /opt/MegaRAID/MegaCli/libstorelibir-2.so.14.07-0 -rwx------ 1 root root 540512 Dec 16 2013 libstorelibir-2.so.14.07-0 -rwxr-xr-x 1 root root 2720320 Dec 16 2013 MegaCli64
以下是MegaCli使用命令 命令使用: #/opt/MegaCli -LDInfo -Lall -aALL 查raid级别 #/opt/MegaCli -AdpAllInfo -aALL 查raid卡信息 #/opt/MegaCli -PDList -aALL 查看硬盘信息 #/opt/MegaCli -AdpBbuCmd -aAll 查看电池信息 #/opt/MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志 #/opt/MegaCli -adpCount 【显示适配器个数】 #/opt/MegaCli -AdpGetTime –aALL 【显示适配器时间】 #/opt/MegaCli -AdpAllInfo -aAll 【显示所有适配器信息】 #/opt/MegaCli -LDInfo -LALL -aAll 【显示所有逻辑磁盘组信息】 #/opt/MegaCli -PDList -aAll 【显示所有的物理信息】 #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】 #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】 #/opt/MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】 #/opt/MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】 #/opt/MegaCli -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】 #/opt/MegaCli -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】[root@F11 MegaCli]# ./MegaCli64 -PDList -aALL Adapter #0 Enclosure Device ID: 32 Slot Number: 0 Enclosure position: 1 Device Id: 0 WWN: 5000CCA03EC7F6AB Sequence Number: 4 Media Error Count: 4 Other Error Count: 9 这两个数值来确定阵列中磁盘是否有问题;Medai Error Count 表示磁盘可能错误,可能是磁盘有坏道,这个值不为0值得注意,数值越大,危险系数越高,Other Error Count 表示磁盘可能存在松动,可能需要重新再插入。MegaCli 可以对阵列中所有的磁盘进行检测,我们可以通过脚本的方式来检测相关参数,从而通知管理人员。 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size: 0 Firmware state: Unconfigured(bad) Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca03ec7f6a9 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI HUS723030ALS640 M440YVKJZ4YK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :38C (100.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 1 Drive's position: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: 1 Device Id: 1 WWN: 5000CCA03EC56C53 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca03ec56c51 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI HUS723030ALS640 M440YVKHKV9K FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :38C (100.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 2 Drive's position: DiskGroup: 0, Span: 0, Arm: 2 Enclosure position: 1 Device Id: 2 WWN: 5000CCA03EC7659B Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca03ec76599 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI HUS723030ALS640 M440YVKJNHGK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :36C (96.80 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 3 Drive's position: DiskGroup: 0, Span: 0, Arm: 3 Enclosure position: 1 Device Id: 3 WWN: 5000CCA03EC8035F Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca03ec8035d SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI HUS723030ALS640 M440YVKK005K FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :34C (93.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 32 Slot Number: 4 Drive's position: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 1 Device Id: 4 WWN: 5000CCA03EC7FFC7 Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size: 0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000cca03ec7ffc5 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: HITACHI HUS723030ALS640 M440YVKJZSSK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :33C (91.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: Unknown Drive has flagged a S.M.A.R.T alert : No 硬盘过多 内容重复 已省略 [root@F11 MegaCli]# ./MegaCli64 -LDInfo -Lall -aALL Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 Size : 8.185 TB Sector Size : 512 Parity Size : 2.728 TB State : Optimal Strip Size : 64 KB Number Of Drives : 4 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only
另外有价值的参考网址: http://blog.chinaunix.net/uid-25135004-id-3139293.html http://blog.csdn.net/smithereensman/article/details/51320499 |
CopyRight 2018-2019 办公设备维修网 版权所有 豫ICP备15022753号-3 |