  服务器有部分硬盘报警 需要更换 刚接手服务器不知道具体情况  百度了一些教程 都不尽人意 查询结果都没有想要的 

后找到一篇文章 地址 http://blog.csdn.net/msdnchina/article/details/52475383 我这里只写与我实际操作有出入的地方 以备复习  cat /proc/scsi/scsi  dmesg | grep -i raid

lsi MegaRAID raid卡管理工具能查如下信息: raid的level, raid是几块物理硬盘构成的, 物理硬盘的制造商.

软件raid:查看raid级别,状态等信息 #cat /proc/mdstat 硬件raid:查看raid的厂商,型号,级别 #cat /proc/scsi/scsi dmesg | grep -i raid

dracut: rd_NO_MD: removing MD RAID activation megaraid_sas 0000:03:00.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 megaraid_sas 0000:03:00.0: setting latency timer to 64 megaraid_sas 0000:03:00.0: FW now in Ready state megaraid_sas 0000:03:00.0: irq 107 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 108 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 109 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 110 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 111 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 112 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 113 for MSI/MSI-X megaraid_sas 0000:03:00.0: irq 114 for MSI/MSI-X megaraid_sas 0000:03:00.0: firmware supports msix    : (16) megaraid_sas 0000:03:00.0: current msix/online cpus    : (8/8) megaraid_sas 0000:03:00.0: RDPQ mode    : (disabled) megaraid_sas 0000:03:00.0: Current firmware maximum commands: 1008     LDIO threshold: 0 megaraid_sas 0000:03:00.0: Init cmd success megaraid_sas 0000:03:00.0: firmware type    : Legacy(64 VD) firmware megaraid_sas 0000:03:00.0: controller type    : MR(512MB) megaraid_sas 0000:03:00.0: Online Controller Reset(OCR)    : Enabled megaraid_sas 0000:03:00.0: Secure JBOD support    : No megaraid_sas 0000:03:00.0: INIT adapter done megaraid_sas 0000:03:00.0: Jbod map is not supported megasas_setup_jbod_map 4967 megaraid_sas 0000:03:00.0: pci id        : (0x1000)/(0x005b)/(0x1028)/(0x1f38) megaraid_sas 0000:03:00.0: unevenspan support    : no megaraid_sas 0000:03:00.0: firmware crash dump    : no megaraid_sas 0000:03:00.0: jbod sync map        : no scsi0 : Avago SAS based MegaRAID driver megaraid_sas 0000:03:00.0: scanning for scsi0... megaraid_sas 0000:03:00.0: 4145 (529973269s/0x0001/CRIT) - VD 00/0 is now DEGRADED megaraid_sas 0000:03:00.0: scanning for scsi0... 软件下载地址http://www.avagotech.com/support/download-search

在搜索框里搜索"megacli",点击确定,找到Management Software and Tools (22) 下的 MegaCLI 5.5 P2  (这是命令行工具),另:lsi已经被avago收购了.

[root@F11 ~]# mv 8-07-14_MegaCLI.zip 123/ [root@F11 ~]# cd 123/ [root@F11 123]# unzip 8-07-14_MegaCLI.zip  Archive:  8-07-14_MegaCLI.zip   inflating: 8.07.14_MegaCLI.txt        inflating: DOS/MegaCLI.exe           extracting: FreeBSD/MegaCLI.zip       extracting: FreeBSD/MegaCli64.zip      inflating: Linux/MegaCli-8.07.14-1.noarch.rpm     inflating: Solaris/MegaCli.pkg        inflating: Windows/MegaCli.exe        inflating: Windows/MegaCli64.exe    [root@F11 123]# ls -lrt total 7824 -rw-r--r-- 1 root root   48298 Jan 19  2014 8.07.14_MegaCLI.txt -rw-r--r-- 1 root root 7939395 Dec  8 10:34 8-07-14_MegaCLI.zip drwxr-xr-x 2 root root    4096 Dec  8 10:36 DOS drwxr-xr-x 2 root root    4096 Dec  8 10:36 FreeBSD drwxr-xr-x 2 root root    4096 Dec  8 10:36 Linux drwxr-xr-x 2 root root    4096 Dec  8 10:36 Solaris drwxr-xr-x 2 root root    4096 Dec  8 10:36 Windows [root@F11 123]# cd Linux/ [root@F11 Linux]# LS -L -bash: LS: command not found [root@F11 Linux]# ls -l total 1516 -rw-r--r-- 1 root root 1549650 Dec 16  2013 MegaCli-8.07.14-1.noarch.rpm [root@F11 Linux]# rpm -ivh MegaCli-8.07.14-1.noarch.rpm  Preparing...                ########################################### [100%]    1:MegaCli                ########################################### [100%] [root@F11 Linux]# cd /opt/MegaRAID/MegaCli/  [root@F11 MegaCli]# ls -l total 3188 -rw-r--r-- 1 root root       0 Dec  8 10:37 install.log lrwxrwxrwx 1 root root      48 Dec  8 10:37 libstorelibir-2.so -> /opt/MegaRAID/MegaCli/libstorelibir-2.so.14.07-0 -rwx------ 1 root root  540512 Dec 16  2013 libstorelibir-2.so.14.07-0 -rwxr-xr-x 1 root root 2720320 Dec 16  2013 MegaCli64

 

以下是MegaCli使用命令

命令使用:   #/opt/MegaCli  -LDInfo -Lall -aALL 查raid级别   #/opt/MegaCli -AdpAllInfo -aALL 查raid卡信息   #/opt/MegaCli -PDList -aALL 查看硬盘信息   #/opt/MegaCli -AdpBbuCmd -aAll 查看电池信息   #/opt/MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志   #/opt/MegaCli -adpCount 【显示适配器个数】   #/opt/MegaCli -AdpGetTime –aALL 【显示适配器时间】   #/opt/MegaCli -AdpAllInfo -aAll    【显示所有适配器信息】   #/opt/MegaCli -LDInfo -LALL -aAll    【显示所有逻辑磁盘组信息】   #/opt/MegaCli -PDList -aAll    【显示所有的物理信息】   #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】   #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】   #/opt/MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】   #/opt/MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL    【显示BBU设计参数】   #/opt/MegaCli -AdpBbuCmd -GetBbuProperties -aALL    【显示当前BBU属性】   #/opt/MegaCli -cfgdsply -aALL    【显示Raid卡型号,Raid设置,Disk相关信息】 

[root@F11 MegaCli]# ./MegaCli64 -PDList -aALL                                         Adapter #0

Enclosure Device ID: 32 Slot Number: 0 Enclosure position: 1 Device Id: 0 WWN: 5000CCA03EC7F6AB Sequence Number: 4 Media Error Count: 4 Other Error Count: 9

这两个数值来确定阵列中磁盘是否有问题;Medai Error Count 表示磁盘可能错误,可能是磁盘有坏道,这个值不为0值得注意,数值越大,危险系数越高,Other Error Count 表示磁盘可能存在松动,可能需要重新再插入。MegaCli 可以对阵列中所有的磁盘进行检测,我们可以通过脚本的方式来检测相关参数,从而通知管理人员。 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS

Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size:  0 Firmware state: Unconfigured(bad) Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on :  N/A SAS Address(0): 0x5000cca03ec7f6a9 SAS Address(1): 0x0 Connected Port Number: 0(path0)  Inquiry Data: HITACHI HUS723030ALS640 M440YVKJZ4YK             FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None  Device Speed: 6.0Gb/s  Link Speed: 6.0Gb/s  Media Type: Hard Disk Device Drive Temperature :38C (100.40 F) PI Eligibility:  No  Drive is formatted for PI information:  No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s  Port-1 : Port status: Active Port's Linkspeed: Unknown  Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32 Slot Number: 1 Drive's position: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: 1 Device Id: 1 WWN: 5000CCA03EC56C53 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS

Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size:  0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on :  N/A SAS Address(0): 0x5000cca03ec56c51 SAS Address(1): 0x0 Connected Port Number: 0(path0)  Inquiry Data: HITACHI HUS723030ALS640 M440YVKHKV9K             FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None  Device Speed: 6.0Gb/s  Link Speed: 6.0Gb/s  Media Type: Hard Disk Device Drive Temperature :38C (100.40 F) PI Eligibility:  No  Drive is formatted for PI information:  No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s  Port-1 : Port status: Active Port's Linkspeed: Unknown  Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32 Slot Number: 2 Drive's position: DiskGroup: 0, Span: 0, Arm: 2 Enclosure position: 1 Device Id: 2 WWN: 5000CCA03EC7659B Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS

Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size:  0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on :  N/A SAS Address(0): 0x5000cca03ec76599 SAS Address(1): 0x0 Connected Port Number: 0(path0)  Inquiry Data: HITACHI HUS723030ALS640 M440YVKJNHGK             FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None  Device Speed: 6.0Gb/s  Link Speed: 6.0Gb/s  Media Type: Hard Disk Device Drive Temperature :36C (96.80 F) PI Eligibility:  No  Drive is formatted for PI information:  No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s  Port-1 : Port status: Active Port's Linkspeed: Unknown  Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32 Slot Number: 3 Drive's position: DiskGroup: 0, Span: 0, Arm: 3 Enclosure position: 1 Device Id: 3 WWN: 5000CCA03EC8035F Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS

Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size:  0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on :  N/A SAS Address(0): 0x5000cca03ec8035d SAS Address(1): 0x0 Connected Port Number: 0(path0)  Inquiry Data: HITACHI HUS723030ALS640 M440YVKK005K             FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None  Device Speed: 6.0Gb/s  Link Speed: 6.0Gb/s  Media Type: Hard Disk Device Drive Temperature :34C (93.20 F) PI Eligibility:  No  Drive is formatted for PI information:  No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s  Port-1 : Port status: Active Port's Linkspeed: Unknown  Drive has flagged a S.M.A.R.T alert : No

Enclosure Device ID: 32 Slot Number: 4 Drive's position: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 1 Device Id: 4 WWN: 5000CCA03EC7FFC7 Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS

Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Sector Size:  0 Firmware state: Online, Spun Up Device Firmware Level: M440 Shield Counter: 0 Successful diagnostics completion on :  N/A SAS Address(0): 0x5000cca03ec7ffc5 SAS Address(1): 0x0 Connected Port Number: 0(path0)  Inquiry Data: HITACHI HUS723030ALS640 M440YVKJZSSK             FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None  Device Speed: 6.0Gb/s  Link Speed: 6.0Gb/s  Media Type: Hard Disk Device Drive Temperature :33C (91.40 F) PI Eligibility:  No  Drive is formatted for PI information:  No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s  Port-1 : Port status: Active Port's Linkspeed: Unknown  Drive has flagged a S.M.A.R.T alert : No

硬盘过多 内容重复 已省略

[root@F11 MegaCli]#  ./MegaCli64 -LDInfo -Lall -aALL                                        

Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name                : RAID Level          : Primary-5, Secondary-0, RAID Level Qualifier-3 Size                : 8.185 TB Sector Size         : 512 Parity Size         : 2.728 TB State               : Optimal Strip Size          : 64 KB Number Of Drives    : 4 Span Depth          : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy   : Disk's Default Encryption Type     : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only  

 